;RSen_C_model##OTHER##;RSen_C_type##OTHER##;RSen_C_description##OTHER##;REN_I Master##OTHER##;RSen_M_c01_diameter##LENGTH##MILLIMETERS;ZZZ_Aansluit_lengte_01_Length##LENGTH##MILLIMETERS;ZZZ_Aansluit_lengte_02_Length##LENGTH##MILLIMETERS;REN_I Max. flow##OTHER##;REN_I Max. velocity##OTHER##;REN_I Maximum pressure loss##OTHER##;REN_I Airflow control##OTHER##;REN_I Detection##OTHER##;REN_I control valve##OTHER##;REN_I Combination_01##OTHER##;REN_I Combination_02##OTHER##;RSen_C_width##LENGTH##MILLIMETERS;RSen_C_length##LENGTH##MILLIMETERS;RSen_C_height##LENGTH##MILLIMETERS;ZZZ_Healthconnector_type_FamilyType_Duct Accessories##OTHER##;RSen_C_code_article##OTHER##;REN_I Info 1##OTHER##;REN_I Info 2##OTHER##;REN_I Info 3##OTHER##;REN_I Info 4##OTHER##;REN_I Info 5##OTHER##;REN_I Info 6##OTHER##
healthconnector - master_renson_d 125;healthconnector;master;renson_master - healthconnector;1;125;26,25;29,25;125 [m3/h];2.8 [m/s];200 [Pa];yes;yes;yes;RENSON (self-commissioning) window ventilation air supply;Exhaust: permanent pressure controlled (centralised) ventilator;172;304;151;GEO_healthconnector - dia 125_renson : standard;66025092;Control valve with integrated silencer for demand controlled mechanical exhaust;Air quality detection via internal electronic sensors;Regulation flow rate based on the measured indoor air quality;Max Flow 125m / h;Combine with Renson (self-regulating) window for ventilation air supply;Can be combined with Exhaust: constant pressure controlled (centralized) fan.
healthconnector - master_renson_d 200;healthconnector;master;renson_master - healthconnector;1;200;46,5;46,5;400 [m3/h];3.5 [m/s];200 [Pa];yes;yes;yes;RENSON (self-commissioning) window ventilation air supply;Exhaust: permanent pressure controlled (centralised) ventilator;253;151;282;GEO_healthconnector - dia 200_renson : standard;66025082;Control valve for demand controlled mechanical exhaust;Air quality detection via internal electronic sensors;Regulation flow rate based on the measured indoor air quality;Max flow 400m / h (= max air speed 3.5m / s);Combine with Renson (self-regulating) window for ventilation air supply;Can be combined with Exhaust: constant pressure controlled (centralized) fan.
healthconnector - master_renson_d 250;healthconnector;master;renson_master - healthconnector;1;250;46,5;46,5;600 [m3/h];3.5 [m/s];200 [Pa];yes;yes;yes;RENSON (self-commissioning) window ventilation air supply;Exhaust: permanent pressure controlled (centralised) ventilator;303;151;332;GEO_healthconnector - dia 250_renson : standard;66028087;Control valve for demand controlled mechanical exhaust;Air quality detection via internal electronic sensors;Regulation flow rate based on the measured indoor air quality;Max flow 600m / h (= max air speed 3.5m / s);Combine with Renson (self-regulating) window for ventilation air supply;Can be combined with Exhaust: constant pressure controlled (centralized) fan.
healthconnector - slave_renson_d 125;healthconnector;slave;renson_slave - healthconnector;0;125;26,25;29,25;125 [m3/h];2.8 [m/s];200 [Pa];yes;No;yes;;;172;304;151;GEO_healthconnector - dia 125_renson : standard;66025093;Compliant control valve without integrated sensors;Slave Health Connector is controlled by the Master Health Connector;;Max Flow 125m / h;;
healthconnector - slave_renson_d 200;healthconnector;slave;renson_slave - healthconnector;0;200;46,5;46,5;400 [m3/h];3.5 [m/s];200 [Pa];yes;No;yes;;;253;151;282;GEO_healthconnector - dia 200_renson : standard;66025083;Compliant control valve without integrated sensors;Slave Health Connector is controlled by the Master Health Connector;;Max flow 400m / h (= max air speed 3.5m / s);;
healthconnector - slave_renson_d 250;healthconnector;slave;renson_slave - healthconnector;0;250;46,5;46,5;600 [m3/h];3.5 [m/s];200 [Pa];yes;No;yes;;;303;151;332;GEO_healthconnector - dia 250_renson : standard;66025088;Compliant control valve without integrated sensors;Slave Health Connector is controlled by the Master Health Connector;;Max flow 600m / h (= max air speed 3.5m / s);;